Motor, Sq Fl Full 2 Speed 1.5 Hp 48y (sqs1152r)

This Product is no longer available

PART#5282-1

MANUFACTURERA. O. Smith

  0 Ratings

product q&a:   Ask a Question  | View Answers (2)

Description Documents1 Q&A2 Reviews
Product Details

MANUFACTURER CODESQS1152R

ALTERNATE PART #'S12073, 177145, 5KCR49SN2095X, 8-177145-04, 8-177145-05, B962, B983, B985, C1312, C48A25A24, EB983, K48M2P105A1, K48M2P106, K48M2P106A1, K48M2PA105A1, K48M2PM101, K48M2PU101, SQS1152R


Product Description
Motor, Sq Fl Full 2 Speed 1.5 Hp 48y (sqs1152r)
Motor Dimensions Motor Dimensions Motor Image Motor Image
Motor Name:
1.5 HP SQS1152R Replacement Pool Motor
HP:
1.5/ .25 HP
Speed:
Dual
RPM:
3450/1725 RPM
Volts:
230 V
Amps:
10/3 amp
Service Factor:
1.47
Total HP:
2.21 HP
Frame:
48Y
Stock #:
SQS1152R
Shaft:
Threaded
Overload Protector:
Auto
Dimension Letter:
AG
Dimensions:
13 - 9/16 in.
Commonly Used On:
Sta-Rite Max-E-Glas, Max-E-Glas II, Dura-Glas, Dura-Glas II, Dyna-Glas, Dyna-Max Pentair Whisperflow, Pinnacle and Anthony AR2 Series
Documents

Recommended wire gauge for motors (111.76 KB)

Please feel free to view our complete library of owners manuals.

Ask a Question
Q&A

Asked on 01/19/2012 by Guest

I'm trying to replace the motor on my pool pump but all these numbers and abbreviations on the motor label are really confusing me. What do they mean?

Answered on 01/19/2012 by Product Specialist Patrick P.

Replacing a pool pump motor is not as difficult as it seems. You can try looking >here >  >if you need help figuring out what the information on your label means. If you are still having difficulty figuring it out you can call us at our toll free number or you can send us a photo of your motor label >here.

Asked on 01/11/2012 by Guest

What is Service Factor?

Answered on 01/11/2012 by Product Specialist Patrick P.

Service Factor(SF) is a multiplier that when multiplied by the horsepower of the motor indicates the total permissible horsepower loading that may be carried when the motor is operating at rated voltage and frequency. The most important thing to remember when replacing a motor is that the replacement motor's horsepower times its service factor must be equal to or greater than the original motor's horsepower times its service factor. The Service Factor rating can be found on the motor label. See Step 4 of our How to Read a Pool Motor Label guide.