Pressure Switch - 062237B

$49.99

IN STOCK
FREE SHIPPING

Part # 6230-32

By Raypak

  5 Average  

Details

Top

Part # 6230-32

Manufacturer Code 062237B

Dimensions 2-5/8" x 1-7/8"

Alternate Part #'s 062237B, 473191005, MSPSEE05Q39, RAY1513584

Product Description

Pressure Switch - 062237B

Top

?     Asked on 8/13/2019 by Robert

Just want to be certain, have a RP2100, model R185, installed in this date range. Manual is effective ‘93 and letter is stamped ‘97. Believe this is the correct pressure sensor, please let me know for sure. Thank you.
 Reply

A  Answered on 8/14/2019 by Industry Professional

Yes, it is the correct replacement.
 Reply


A  Answered on 8/13/2019 by Industry Professional

We show the pressure switch to be either a 009133F 11 psi ( 47-197-1096 ) or a 006737F 1.7 psi ( 47-197-1462 ) depending on the installation of the heater. Deck level, the 1.7 psi is fine, below water level may require the 11 psi.
 Reply


?     Asked on 7/30/2019 by Philip miracle

Will this fit model 266 raypak
 Reply

A  Answered on 7/30/2019 by InyoPools Product Specialist Lennox H.

Hi, Philip. This pressure switch will NOT work with the RP2100 R266A model. You will need P/N 006737F
 Reply


?     Asked on 7/3/2018 by robyn

What is the difference between this model number and the model number in the manual 006737f? Is 6737f OEM ?
 Reply

A  Answered on 7/3/2018 by InyoPools Product Specialist Lennox H.

Hi, Robyn. The specifications are different, this Pressure Switch - 062237B is used with the older Raypak models, Part # 006737F is used with the newer models. 
 Reply


?     Asked on 8/29/2016 by Greg Allton

Pilot light is on but the burner won't light. Switch is on temp. Switch is up to where heat is called for but will not fire the burner. Is there a switch that tells the unit water pressure is up and it's ok to fire. I need to get this unit running.
 Reply

A  Answered on 8/31/2016 by InyoPools Product Specialist Stacey M.

Hello Greg, you might want to troubleshoot with Raypak 805-278-5300 just in case there might be a misc part.
 Reply


?     Asked on 10/8/2015 by

is this pressure switch on a Raypak C-R406A-EN-C? If so where is located
 Reply

A  Answered on 10/9/2015 by InyoPools Product Specialist Lennox H.

Hi, The Pressure Switch (006737F) would be the correct pressure switch for the Raypak C-R406A-EN-C Heater. It is located at the top of the Inlet/outlet Header.
 Reply


?     Asked on 7/27/2014 by Guest

I need a new pressure switch for my Raypak RP2100 Pool-Spa heater that was installed in 1998. Is this the proper replacement pressure switch?
 Reply

A  Answered on 7/27/2014 by InyoPools Product Specialist Patrick P.

Yes this would be the correct replacement pressure switch for the Raypak RP2100 Pool-Spa heater.
 Reply