Model # 009833

Dimensions 18-1/4" x 11-1/4"

Product Description


Compatible for indoor or outdoor installation 
For use with all Raypak Digital models, sizes 206A - 408.  The D-2 replaces the standard draft hood. 

Certified 
The D-2 Power Vent assembly is tested and certified to the latest edition of the American National Standard ANSI Z21.56 for pool heaters. 

Through-the-Wall Capable

The D-2 Power Vent assembly is a Category III mechanical draft venting system that operates with a positive vent static pressure and with a vent gas temperature that avoids excessive condensate production in the vent. All sizes are capable of relieving flue gases up to a maximum of 100 equivalent feet of vent length. All models have a 4” diameter exhaust connection and can be sidewall terminated. Using field-supplied cat III-certified vent material. Use the factory-supplied screened elbow as a downturned sidewall vent termination. 

Multi-Position
Using a field-supplied adjustable 90° elbow, the flue gases may be discharged in any direction (see D-2 Power Vent manual for details). Or simply remove the elbow for vertical venting. 

Dual-Voltage Induced-Draft Blower (120/240 VAC)

Factory set for 240 volts. Can be rewired in the field for 120v operation. 

Safety at Its Best 
The D-2 Power Vent is equipped with a draft proving switch. This switch ensures that the blower is operating before operating your heater. It is also equipped with a solid state control that allows the blower to purge any residual gas buildup in the heater after the heater has shut down. 

Product Specifications

Volts:
240 V
Model:
336A-407A
Top

?     Asked on 6/19/2019 by judy

I have a raypak pool heater indoor and am looking for a power vent for 106 model. I saw one on your website but now can't find it. Cost ? where can I find it?
 Reply

A  Answered on 6/20/2019 by InyoPools Product Specialist Lennox H.

Hi, Judy.  There is not a power vent for the Raypak 106A model, only an Outdoor High Wind Top - 014718. The Raypak 106A cannot be installed indoors. 
 Reply


?     Asked on 11/30/2016 by dave sample

I wanted to be sure the D2 power vent is what I need for this product. Raypak Heater 407,000 BTU COMM Low NOx ASME NG (009295)
 Reply

A  Answered on 11/30/2016 by InyoPools Product Specialist Adam Y.

Good  afternoon Dave, Yes ,The D2 is the correct vent. It will work with  all Raypak Digital models, sizes 206A - 408.  The D-2 replaces the standard draft hood.
 Reply