This PC board control kit is designed for use with Digital Gas Heater. Features a 2-line 16 character LCD display with plain text diagnostics. It has improved flame sensing capabilities, an internal fuse, and a service menu to aid in troubleshooting and maintenance. It is the first ever flame signal strength indicator that is graphical and It is easy to use. This new sensing and diagnostic capability will help reduce unnecessary parts change outs. It has the ability to monitor the 24-Volt power supply and provide useful diagnostic feedback. Packaged with an extensive list of parts, the kit includes a PC control board and a remote wire harness, designed as a seven pin plug. It also includes an LCD gasket for added protection against water damage.

Top

?     Asked on 9/29/2019 by

I have a Raypak 266 pool heater. It worked perfectly for three weeks and now it shows a "flo switch" problem. I have checked the flow switch with a meter, flow switch works fine. The unit starts fine, burns for about 1 minute then shuts the gas valve and shows the flow switch again. I even jumpered the two wires at the flow switch and same thing happens. Starts fine, runs a minute then shuts the gas valve. Could the problem be with the flame sensing wire or is this a board issue. Warrantee?
 Reply

A  Answered on 9/30/2019 by Industry Professional

If it is reading “Water Switch Open” then it usually means that there is a water flow issue. The filter should be backwashed and/or cleaned, the strainer basket and skimmer basket should be emptied, and adequate flow confirmed. If using a variable speed or two speed pump, then the rpms may need to be increased. If adequate water flow is confirmed and the issue persists, then check the connection at the P2 terminal on PC Board by unplugging the connector and plugging it back in to ensure a snug connection. If the connection is sloppy or loose, then the pins on the PC board could be faulty.
 Reply


?     Asked on 8/12/2019 by John

Since purchase of our Raypak heater in July 2014, the PC Board Controller 013464F has been replaced in 2016 and again in 2018 and has failed again. Including the original, when I have it replaced again, it will be the forth unit in the past 5 years! Is this a common occurrence with Raypak?
 Reply

A  Answered on 8/14/2019 by Industry Professional

No, this is not common, we recommend you have a professional technician do a service call.
 Reply


?     Asked on 8/11/2019 by Darcy

I got this unit PCB Control about three weeks ago now its not working first the rollout sw. burned out replaced it then no pilot light replaced pilot light and now its showing main ignition failure. how do I get another PCB Control ?
 Reply

A  Answered on 8/14/2019 by Industry Professional

First inspect your heat exchanger, is it clean? Soot? It may not be your PCB board.
 Reply


?     Asked on 8/7/2019 by Darcy Simoni

I got a new mother board and put it in my pool heater it worked fine for two weeks now its not working at all the screen shows nothing its blank
 Reply

A  Answered on 8/7/2019 by InyoPools Product Specialist Lennox H.

Hi, Darcy. The unit will have to be troubleshoot confirming that you're getting 24 volts to the Board. If not, you will need to replace the Transformer - 006736F. If the board is getting the required 24 volts, then the Board is bad. 
 Reply


?     Asked on 7/15/2019 by Darcy

Is this the right mother board Ray Pak model P-M206A-EN-C
 Reply

A  Answered on 7/16/2019 by InyoPools Product Specialist Lennox H.

Hi, Darcy. Yes, if your model was manufactured after 11/01/04.
 Reply


?     Asked on 7/6/2019 by Mike

I have a RP 2100 P-R335A-EP Serial #0103067189 will this pc board work?
 Reply

A  Answered on 7/11/2019 by Industry Professional

We show the pc board for your model heater as being discontinued. see snip image showing models it was used in.

 Reply


?     Asked on 7/5/2019 by Russ Strufing

I have a rp 2100 185a natural gas that I think the board has gone out on I am having trouble finding a correct replacement pc board # Could 006700F be the #
 Reply

A  Answered on 7/5/2019 by InyoPools Product Specialist Lennox H.

Hi, Russ. The replacement PCB P/N is 017108F. We will have to reach out to Raypak to see if it is available. 
 Reply


?     Asked on 6/24/2019 by Brian

Hi, I have rp2100 model # p-r 335a - EN serial# 0308020892. My heater turns on by iteslf and immediately goes to highest heat setting of 104 degrees. is this the right board for me? If so, will it solve my problem? Thanks

 Reply

A  Answered on 6/24/2019 by InyoPools Product Specialist Lennox H.

Hi, Brian. This PCB Control Kit is the correct part. It will resolve the issue if it's not being controlled by an external controller.
 Reply

  • Commented on 6/28/2019 by Product Owner

    Thanks, I got the board, looks good but my p1 sensor wire has 2 female connector and this board has 3 male connector. Am I still good and could I just order a new wire to fit the board? If so what's the wire called. Thanks
     Reply

    • Commented on 7/11/2019 by InyoPools Product Specialist Lennox H.

      Brian, You will need the Wiring Harness - 006738F
       Reply


?     Asked on 6/23/2019 by Brian

Hi, I have rp2100 p-r335a-en model# 03080208. My heater turns on by itself and immediately goes to the highest heat setting at 104 degrees. Is this the right part for me and do you think this will solve my problem? Thanks
 Reply

A  Answered on 10/10/2019 by Industry Professional

this question was answered on 06/24/19 we suggest you go to the link provided & check out the troubleshooting guides provided by the mfg. https://www.raypak.com/documents/
 Reply


?     Asked on 6/23/2019 by Michelle Huttemann

Raypak model # P-R 405B-EN Serial # 0401089504 Manufacturing date 1/04 Error code EEP Would you please tell me which Board/Control IID Unit to purchase as a replacement. Part # 010253F is no longer available. Thank you
 Reply

A  Answered on 6/23/2019 by InyoPools Product Specialist Lennox H.

Hi, Michelle. Based on the info provided this PCB Control & 3 Wire, Kit - 013464F is compatible with your model unit.
 Reply


?     Asked on 6/20/2019 by DJ

I have Raypak Model C-R336A-EN-C serial number 0703263133. Is this the correct part?
 Reply

A  Answered on 6/21/2019 by InyoPools Product Specialist Matt S.

Yes, this is the correct replacement PCB control for the CR336AENC Raypak ASME.
 Reply


?     Asked on 6/7/2019 by RICHARD DOYLE

I have a Raypak model 406a manufactured in 2008. will this item work in my heater ?
 Reply

A  Answered on 6/7/2019 by InyoPools Product Specialist Lennox H.

Hi, Richard. This is compatible with the Raypak 406A unit manufactured in 2008. 
 Reply


?     Asked on 5/25/2019 by

Will this work with model (P-M407A-EN-C) Serial Number beginning 080302. The upper row of the display does not show anything anymore. Is there a way to repair just the display? Thank you in advance.
 Reply

A  Answered on 5/28/2019 by Industry Professional

This 013464F is the correct item.
 Reply

  • Commented on 5/28/2019 by Product Owner

    Do I understand that there is no way to replace the display only if the controls are working fine?
     Reply

    • Commented on 5/29/2019 by InyoPools Product Specialist Patrick P.

      That is correct if your display goes out you need to replace it with this entire kit.
       Reply

      • Commented on 6/7/2019 by Product Owner

        Not true. The display can be purchased separately and is easy to install. It came with simple instructions. If a novice like me can do it, it's EASY! You need NOT purchase the entire circuit board UNLESS you have failures other than the display.
         Reply

        • Commented on 6/8/2019 by InyoPools Product Specialist Patrick P.

          Hi Joe, Could you give the part # for the display only that you used so we can update our records, thanks so much!
           Reply


?     Asked on 4/15/2019 by Dan Mock

I have a Raypak P-R406A-EP-C heater that has a bad display. What part do I need to replace it and is there anything special about installing the new part? Thanks
 Reply

A  Answered on 5/7/2019 by Raypak

Sorry for the late reply but could you let us know how old is the unit?
 Reply


?     Asked on 3/29/2019 by SCOTT BEATTY

Raypak Model P-R406A-EN-C Serial # 0810041575 Need Pc Board Control Digital Gas Heater, is this the right board for this heater? Thank you
 Reply

A  Answered on 3/29/2019 by InyoPools Product Specialist Lennox H.

Hi, Scott. This is the correct replacement board based on your model and serial number. 
 Reply


?     Asked on 11/30/2018 by David Klein

Is this a replacement for 601944, 1134-700? Thank you in advance for your response.
 Reply

A  Answered on 12/3/2018 by InyoPools Product Specialist Lennox H.

Hi, David. Yes, this is the correct replacement board based on the info provided. 
 Reply


?     Asked on 6/15/2018 by Jeff

I have a raypak model # P-M206A-EN-C s/n 1003074892 display not readable heater works fine just want to make sure I order correct part
 Reply

A  Answered on 6/15/2018 by InyoPools Product Specialist Lennox H.

Hi, Jeff. Based on the model and serial number, you will need Part # 010253F
 Reply


?     Asked on 5/8/2018 by Gene

Hi, I bought item #014941 - Raypak Heater 406,000 BTU's NG ELE W/ Cupro-Nickel Heat Exchanger from you guys a couple years ago. When I try to fire up the heater, it doesn't seem to sense when the burners are lit. Everything operates fine until after the burners light, then it turns itself off and re-lights itself over and over. Is this the part that will fix this issue?
 Reply

A  Answered on 5/8/2018 by InyoPools Product Specialist Lennox H.

Hi, Gene. It's possible if you've reset the PC board and checked the continuity of ignition cable and ground wire, and that the pilot flame covers flame rod and is steady and blue. If these two checks out then the PC Board is bad. You will need Part #010253F for your model heater. 
 Reply


?     Asked on 3/19/2018 by Terry

Is this board compatible with the "Control Panel, Iid, Digital (006739f)"? This is the original lid and Switch/Decal membrane on the Raypak 2100 model 405A. The LED on my board is cracked. The heater still works but I have no idea of temp/set point/mode of operation. It appears I need this new board which is compatible with the 405A. So if I purchase this board, do I also purchase the newer 013492F membrane switch or will the 006739f work.
 Reply

A  Answered on 3/27/2018 by InyoPools Product Specialist Lennox H.

Hi, Terry. This PCB - 013464F is not compatible with the Control Panel IID - 006739F. The correct PCB is part # 010253F
 Reply


?     Asked on 8/19/2017 by MIchael

Hi, I have a Raypak PR266A EN-C heater and it just stopped heating, When you activate the heat the display shows "CFH" and then "SPK" and the burners do not light. I replaced the standing pilot and tubing but still not firing. Checked 24v transformer and it appears to be ok. So I'm thinking its either the gas valve and or the PC board. Can you recommend the correct replacement parts for both?
 Reply

A  Answered on 9/28/2017 by InyoPools Product Specialist Lennox H.

Hi, Michael. To find out if the gas valve or PCB is the issue; you'll need to check for 24 VAC across MV-MV/PV terminals. If no voltage, replace PC board. Also, check electrical connections between PC board and gas control. If okay, replace gas valve or gas control operator, i.e. pilot gas valve, flow switch etc.
 Reply


?     Asked on 5/30/2017 by Tom C

I have a rheem/raypak heater Model#P-M266A-EN-C Serial#0412009103. I'm getting a GVO error which means Gas Valve Open. I was told a new board Raypak#013463F would fix this problem?
 Reply

A  Answered on 6/4/2017 by InyoPools Product Specialist Lennox H.

Hi, Tom. To find if the problem is the PCB or the Gas valve, follow these steps.1. Turn power OFF and disconnect Ignition Wire and Gas Valve wires from board.2. Power ON and watch for spark at module.3. If no spark, turn power OFF, and replace board.4. If spark is observed, turn off power and reconnect wires. The unit should fire.5. If unit does not fire and code reappears, power OFF, disconnect valve wires from board and remove MV, PV, and ground wires. Clean and reconnect.7. If unit does not fire, replace the gas valve.8. Low power to transformer can cause a GVO fault.
 Reply


?     Asked on 3/27/2017 by 337A

does the replacement PC board come with the 3 wire sensor as well? I was given part number 013464F. Is this everything I need to replace the PC board when I order this or is there something else?
 Reply

A  Answered on 3/30/2017 by InyoPools Product Specialist Lennox H.

Hi, The part does include the 3-wire kit along with everything needed to install the board. Some customers usually replace the decal if faded when replacing this board.
 Reply


?     Asked on 6/25/2016 by Rick

I have a Rheem propane pool heater - Item #009975 and S/N 1104109848. I'm not sure when it was manufactured (I think we installed it 4-5 years ago). I need to replace the PC board. My owners manual says the part is 013489F. Will the 013464 work?
 Reply

A  Answered on 7/2/2016 by InyoPools Product Specialist Lennox H.

Hi Rick, I was not able to cross reference item # 009975 to a specific model or have the ability to use the serial number to search for an item. The 013489F and  013464 are not interchangeable, you will have to use p/n 013489F.
 Reply


?     Asked on 5/21/2016 by Kimberly Yoder

looking to replace and not sure what i need for a rheem ray pak heater ...my display is not readable, have no idea temp settings? Serial #0812047113 Model #pm336aenx BTU/HR inp 332500....ignition board or control panel kit???
 Reply

A  Answered on 5/22/2016 by InyoPools Product Specialist Matt S.

Kimberly, if you need the display, the correct part number is the 013464F PC Board Controller and 3-Wire Kit. In our picture, we do not show the LCD screen on the backside of the board.
 Reply


?     Asked on 4/27/2016 by Lynn

pool Heater model 266A don't find part # 013464F on control board. Has 601944 ID 026 1134-700 0714N502317 What is replacement part and how assured it is bad?
 Reply

A  Answered on 4/28/2016 by InyoPools Product Specialist Lennox H.

Hi Lynn, In order to get you the correct PCB, we will need to know the year that your unit was manufactured. We're unable to use the info you provided to located the correct replacement PCB.
 Reply


?     Asked on 3/12/2016 by

is the board 405b work in a 406a water heater?
 Reply

A  Answered on 3/17/2016 by InyoPools Product Specialist Lennox H.

Hi, This PC Board (013464F) can be used in the R405B manufacture date 11/03-10/04 and R406A manufacture date 11/04- current units.
 Reply


?     Asked on 6/16/2015 by Dave

Is this part a plug and play replacement for the older style board that does not have the replaceable LCD display? P/N 601769
 Reply

A  Answered on 6/18/2015 by InyoPools Product Specialist Lennox H.

Dave, This PC BOARD CONTROLLER & 3-WIRE-KIT will work on all models that have a digital display and electronic ignition.
 Reply


?     Asked on 6/11/2015 by Neil Martin

Does this work for the propane milli volt model? Does it include the display? Thanks.
 Reply

A  Answered on 6/12/2015 by InyoPools Product Specialist Patrick P.

Hi Neil, this board does include the display but it does not work with the milivolt units only the electronic ignition (IID) units.