?     Asked on 4/15/2019 by Daniel Gillespie

Will this replace WG-430-3
 Reply

A  Answered on 4/15/2019 by InyoPools Product Specialist Lennox H.

Hi, Daniel. Unfortunately, this motor will not replace P/N WG-430-3. 
 Reply


?     Asked on 2/12/2019 by Rick

Hi I have a never used (new) T104P3 timer that I would like to use but need to change it to a 120 volt clock motor. Thanks for any advice.
 Reply

A  Answered on 2/13/2019 by InyoPools Product Specialist Lennox H.

Hi, Rick. Unfortunately, replacing just the clock motor on the T104P3 time will not convert it to 115 volts. You will need to purchase a T101M mechanism. 
 Reply


?     Asked on 7/23/2018 by Jeffrey

Will this work for a T104R?
 Reply

A  Answered on 7/23/2018 by InyoPools Product Specialist Hector F.

The T104R series Intermatic timers are 220 volts so the correct time clock motor would be part number 3680-02
 Reply


?     Asked on 8/27/2017 by Dennis

what is the replacement motor for T104R201
 Reply

A  Answered on 8/28/2017 by InyoPools Product Specialist Lennox H.

Hi, Dennis. This Time Clock Motor WG1570-10 will work with the T104R201 timer. 
 Reply


?     Asked on 6/7/2017 by John

I have the INTERMATIC PF1202T, either clock is not working, I stuck finger in and the mechanism looks like loose, What is the correct time clock for both sides?
 Reply

A  Answered on 6/7/2017 by InyoPools Product Specialist Patrick P.

Hi, John, The proper replacement timer is the T104M Replacement Timer. If you just wanted the motor then the WG1573-10 Replacement Motor is what you will need.
 Reply


A  Answered on 6/7/2017 by Product Owner

John, I have repaired my clock mechanism very easily however it seems unusual for neither clock to be working. Because it is so easy to do I would shut down the power to the unit and take apert the clocks separately. The gears inside the mechanism do seem to strip on occasion but not at the same time. Swap the mechanism between the two clocks and see if either one works. If neither still works ask Inyo if there is something in common to make them both inoperable.
 Reply


?     Asked on 5/15/2017 by Kathy

Clock on timer not working. Model #t101r. Is there a part?
 Reply

A  Answered on 5/16/2017 by InyoPools Product Specialist Lennox H.

Hi, Kathy. Replacing the WG1570-10D motor will fix your issue.
 Reply


?     Asked on 8/24/2016 by Bernice Castillo

i hear the motor running, but the dial switch gears are not moving. Do I need to replace only the dial switch or the whole time clock
 Reply

A  Answered on 8/30/2016 by InyoPools Product Specialist Lennox H.

Hi Bernice, I would recommend replacing the entire mechanism if it's more than 5 years old.
 Reply


?     Asked on 5/10/2016 by Alan

I have the T40004RT3 enclosure. The 120 v time clock is not working. (pool lights) Can you tell me the motor part number? Thank you
 Reply

A  Answered on 5/13/2016 by InyoPools Product Specialist Lennox H.

Hi Alan, This motor (WG1570-10D) will work with 120 volt mechanism on the T40004RT3.
 Reply


?     Asked on 8/26/2015 by Ben H

I have a PF1202T Pool Equipment Control panel (https://www.1000bulbs.com/pdf/Inter-PF1202T-Operating.pdf) and the clock is not working. I am pretty sure that the clock motor is not working. Is this product the correct motor for my Control panel?
 Reply

A  Answered on 8/28/2015 by InyoPools Product Specialist Lennox H.

Hi Ben, The Intermatic WG1570-10D time clock motor will be the correct clock motor for your PF1202T Control Panel.
 Reply


?     Asked on 7/3/2015 by Cisco

Will this work with my T101R?
 Reply

A  Answered on 7/4/2015 by InyoPools Product Specialist Patrick P.

Hi Cisco, yes this is correct motor replacement for your T101R time clock.
 Reply


?     Asked on 4/9/2015 by Tim

Which motor replaces wg.433.3?
 Reply

A  Answered on 4/10/2015 by InyoPools Product Specialist Robert M.

Hello Tim - The replacement is WG433-20D.
 Reply


?     Asked on 3/3/2015 by Robert

Hello, I have a T40004RT1. Not sure the age as it was here when I moved in. The dial is not rotating. I can run the pump by turning the switch manually but must shut it down to prevent continued running. I believe it is the time clock motor otherwise known as WG1570-10D. Your thoughts? Thanks....RObert
 Reply

A  Answered on 3/4/2015 by InyoPools Product Specialist Robert M.

Hello Robert - The WG1570-10D is used on the T101M mechanism. The T101M mechanism is not used in the T40004RT1. The T104M is used in the T40004RT1. The correct timer motor would be WG1573.