PERFLEX, XStream & Regenx DIVERTER VALVE WG 1.5" (SP0727)

$58.99

IN STOCK
FREE SHIPPING

Part # 4820-63

By Hayward Pool Products

  4.75 Average  

Details

Top

Part # 4820-63

Manufacturer Code SP0727

Alternate Part #'s SP0727, SP727

Product Description

For heavy spring clean-ups, we recommended using a Hayward SP0727 diverter valve to bypass the filter and accelerate the clean-up process. The SP0727 can be used with PerFlex, ReGenex and XStream filters. This valve has 3 ports on it, the valve would screw into the disharge side of your pump and you can have the handle turned so the return water goes through your filter or you can turn the valve in the opposite direction so the dirty water goes to waste and bypasses your filter, this is very helpful when vacuuming or for heavy spring clean up.

Top

?     Asked on 5/16/2018 by Swimmer Jo

Can a diverter be installed on a Hayward X treme 1000? Where do you place it please....Thank you in advance
 Reply

A  Answered on 5/17/2018 by InyoPools Product Specialist Lennox H.

Hi, Swimmer Jo. Yes, it can. It will go between the pump and filter. 
 Reply


?     Asked on 6/12/2017 by Joe

does the SP0727 valve has a connection for the automatic chlorinator.?
 Reply

A  Answered on 7/22/2017 by InyoPools Product Specialist Alex V.

Joe, This does not have a chlorinator connection. 
 Reply


?     Asked on 4/29/2017 by Ann

Will this valve work on the Hayward 40 Sq. Ft. Filter W/ 1 HP Pump? Would I need anything else to install it on this pump filter system? Does it connect between the pump and filter?
 Reply

A  Answered on 4/30/2017 by InyoPools Product Specialist Lennox H.

Hi, Ann. The valve can be used with the C4001575XES pump and filter. You can replace this valve with the union connector that comes with the system.
 Reply


?     Asked on 7/20/2016 by Eric

I have a Hayward regenx with a RG70 grid filter but do not have a backwash valve which one should I get? Thanks.
 Reply

A  Answered on 7/20/2016 by InyoPools Product Specialist Alan M.

Hello Eric, This valve is a diverter valve to bypass the filter, but is not considered a "backwash" valve. The backwash feature on DE/Sand filters removes the dirty water from the tank and expels it through a waste line. This valve would screw into the discharge side of your pump and you can have the handle turned so the return water goes through your filter or you can turn the valve in the opposite direction so the dirty water goes to waste and bypasses your filter.
 Reply


?     Asked on 7/20/2016 by Eric

I have a Hayward regenx with a RG70 grid filter but do not have a backwash valve which one should I get? Thanks.
 Reply

A  Answered on 7/20/2016 by InyoPools Product Specialist Alan M.

Hello Eric, This valve is a diverter valve to bypass the filter, but is not considered a "backwash" valve. The backwash feature on DE/Sand filters removes the dirty water from the tank and expels it through a waste line. This valve would screw into the discharge side of your pump and you can have the handle turned so the return water goes through your filter or you can turn the valve in the opposite direction so the dirty water goes to waste and bypasses your filter.
 Reply


?     Asked on 9/9/2015 by

I have a Haywood ec65 with fingers.Is there an upgrade to use a diverter valve instead of the bump to make it easier and clean the fingers better?
 Reply

A  Answered on 9/14/2015 by InyoPools Product Specialist Lennox H.

Hi, The "Bump" feature is the only way to backwash the Hayward Perflex filters. The Perflex XStream & Regenx Diverter Valve WG 1.5" (SP0727) is a valve that can be install so that you back vacuum or drain you pool without going through the filter.
 Reply


?     Asked on 6/5/2015 by bill

do you need extra parts to install unit or will the unit go on a ec 65 system 3.. looks as if need more fittings and pvc pipe...........
 Reply

A  Answered on 6/15/2015 by InyoPools Product Specialist Lennox H.

Bill, It all depends on what you're doing, but extra materials will be required.
 Reply


?     Asked on 9/19/2014 by Guest

Can this valve be used on a perplex ec75 for an in ground pool. It says on Hayward's site for above ground pools
 Reply

A  Answered on 9/19/2014 by InyoPools Product Specialist Patrick P.

Yes this can be used with in ground pools. The Perflex is most commonly (in smaller sizes) used in above ground pools. So I'm sure that's what they were referring to.
 Reply


?     Asked on 5/2/2013 by Guest

Do you sell a replacement nut for the Hayward SP727 valve?
 Reply

A  Answered on 5/2/2013 by InyoPools Product Specialist Patrick P.

Yes, you can find the nut here: http://www.inyopools.com/Products/07501352027853.htm
 Reply


Top

Review Summary

 (Average 4.75  out of 5 stars)
4 Rating
5 star:
 
(3)
4 star:
 
(1)
3 star:
 
(0)
2 star:
 
(0)
1 star:
 
(0)

The Most Helpful Review


The Most Recent Reviews