$259.99

Qty:

By Hayward Pool Products


Details

Top

Part # 2807-21

Manufacturer Code GLX-XFMR

Dimensions 4-1/8" X 3-3/8"

Alternate Part #'s GLXXFMR, 43-150-1024, GLD-30-612, GOLGLX-XFMR, HPPGLXXFMR

Product Description

Transformer - GLX-XFMR

Applications:
Aqua Rite
Aqua Rite Pro
Aqua Trol

Also Accommodates Control Models:
Aqua Logic
Aqua Plus
OnCommand

Top

?     Asked on 5/13/2015by Inyo Visitor

My control unit is no longer producing chlorine all LEDs are off however the display is still working. what are the specs for the secondary voltage lead taps so I can figure out if the transformer is bad or not
 Reply

A  Answered on 5/15/2015 by InyoPools Product Specialist Lennox H.

Based off the information in the Hayward AquaRite Diagnostics Manual the transformer should register 2.0-2.9 Ohms.
 Reply


?     Asked on 7/25/2015by paul

My power light is off but my displays still are working. I have replaced the PCB board but that did not fix the issue Is it possible the transformer is bad and needs replacing on my Aqua Rite automatic chlorinator??
 Reply

A  Answered on 7/27/2015 by InyoPools Product Specialist Lennox H.

Hi Paul, I would recommend having some out to inspect the panel or use the AquaRite Troubleshooting Guide to find out what is causing the issue.
 Reply


?     Asked on 7/20/2016by Tony

What are signs that the transformer is failing?
 Reply

A  Answered on 7/23/2016 by InyoPools Product Specialist Lennox H.

Hi Tony, The transformer is not going to slowly fail it will either put out the correct voltage or not. On page 10 of the Aqua-Rite Troubleshooting Guide provides you with info on testing the transformer.
 Reply


?     Asked on 5/11/2017by Gil

The power is not coming on we show after pushing Diaognostic button 2 times power is only 7-14 can this be a bad transformer, power into was checked is 110v
 Reply

A  Answered on 5/13/2017 by InyoPools Product Specialist Patrick P.

Hi Gil, Here is a really good AquaRite Troubleshooting Manual I would follow the steps outlined in the manual. This isn't the normal useless troubleshooting guide, it actually gives great flow charts to isolate the problem.
 Reply


?     Asked on 10/18/2017by mark

How do I know if my transformer is bad?
 Reply

A  Answered on 10/18/2017 by InyoPools Product Specialist Lennox H.

Hi, Mark. You can use the AquaRite Troubleshooting Manual to test the transformer. 
 Reply


Top
Difficulty

Est. Repair Time

Less than 1 hr

Tools Needed

Screwdriver, Pliers

AquaRite System wasn't working as it should

Written on 8/1/2023 by Guest

I decided after 18 years that it was time to replace all the parts in the AquaRite Panel.
1 - I shut off the power to the system
2 - I removed the Metal Panel
3 - I removed the Display Board
4 - I disconnectd the Electrical to the Main Board
5 - I removed all the wires from the Transformer to the Main Board
6 - I removed the Main Board
7 - I removed the Transformer
8 - I Installed the New Transformer
9 - I reinstalled a New Main Board
10 - I reattached all the wires to the Board and 2 other locations as described in the instructions provided
11 - I reattached the electrical wires
12 - I reinstalled a New Display Board.
13 - I plugged the Flow Meter Line to the bottom of the Main Board
14 - I plugged in the Salt Cell
15 - I replaced the front panel to the AquaRite Box
16 - I turned on the Power to the System
17 - I turned on the pump
18 - I checked to make sure the correct Salt Cell was noted in diagnostics.
19. All runs fine now

Were these instructions helpful? 
 

Top

Review Summary

 (Average 5  out of 5 stars)
1 Ratings
5 star:
 
(1)
4 star:
 
(0)
3 star:
 
(0)
2 star:
 
(0)
1 star:
 
(0)

The Most Recent Reviews