Corrosion Resistant Check Valve 2" Inside 2-1/2" Outside 2 Lb. Spring - 25830-400-000

$43.99

IN STOCK
FREE SHIPPING

Part # 25830-400-000

By Custom Molded Products


Details

Top

Part # 25830-400-000

Product Description

Check Valves - Serviceable Check Valves, Corrosion Resistant

  • 1-1/2" Socket
  • 2" Spigot
  • CPVC Body (Black)
  • Clear Lid
  • Lock Nut
  • Corrosion Proof Pin and Spring
  • Corrosion Proof Hastelloy Spring -  For high stress and corrosive environments

For more Pool Valves

Product Specifications

Inside Diameter:
2 in.
Outside Diameter:
2 1/2 in.
Top

?     Asked on 9/11/2018 by

Can I just get the piece with the flapper.
 Reply

A  Answered on 9/12/2018 by InyoPools Product Specialist Lennox H.

Hi. The replacement Flapper Assembly and Cover - 28530-350-800 can be special ordered.
 Reply


?     Asked on 7/19/2017 by Dave

I`m installing 1/2 hp whisperfow EE, then 150 square foot swim clear cartridge filter Then CHECKVALVE Then 200 sq ft solar on roof and then possibly heater [for winter heating], and last del ozone and degasser unit. What type and spring strength check valve should I use. Thanks Dave
 Reply

A  Answered on 7/22/2017 by InyoPools Product Specialist Lennox H.

Hi, Dave. With a 1/2 HP pump, I would not recommend the anything over 1 pound depending on which part of the system it's being placed. 
 Reply


?     Asked on 4/20/2017 by

I'm installing a heatpump and 1.65hp variable speed pump and need to install a check valve between the heater and clorinator. They recommend a 1/3 lb check valve, I wanted to know if this 2 ld valve would work or if you would recommend a different one?
 Reply

A  Answered on 4/20/2017 by InyoPools Product Specialist Lennox H.

Hi. This 2lb check valve will work if your pump is sufficed to open the spring. I would recommend the Clear Check Valve 2" - 1/2 lb. w/ Unions - 1700C20.
 Reply


?     Asked on 4/11/2017 by

I'm installing a heatpump and 1.65hp variable speed pump and need to install a check valve between the heater and clorinator. They recommend a 1/3 lb check valve, I wanted to know if this 2 ld valve would work or if you would recommend a different one?
 Reply

A  Answered on 4/11/2017 by InyoPools Product Specialist Scott W.

Part number 170020, which is a 1/2 pound check valve, is going to be the closest to 1/3 pound check valve that we carry.
 Reply


?     Asked on 7/14/2016 by STEVE OLIVIER

can the check valve mount either vertical or horizontally ?
 Reply

A  Answered on 7/14/2016 by InyoPools Product Specialist Alan M.

Yes this check valve can be installed vertically or horizontally.
 Reply


?     Asked on 7/5/2016 by Bob

I have plumbed a Sta-Rite 1hp Max Pro pump and a Sta-Rite System 3 500 cartridge filter with an off line CL220 Hayward chlorinator (all recently purchased from you). Everything runs fine except all water drains back in pool when turned off. What I read tells me I need a check valve to fix the problem (none in plumbing). What do you recommend and where should it be installed? Pump and filter about 3 ft above pool and draining seems to be from both filter and pump sides of plumbing.
 Reply

A  Answered on 7/9/2016 by InyoPools Product Specialist Lennox H.

Hi Bob, You can install a check valve on the return side, install a check valve on the suction side can be very tricky. You do have a self priming pump which  good for applications like yours. Depending on the feet of head you do not want to add more restriction on the suction side of the pump.
 Reply


?     Asked on 2/20/2015 by Carl

What is the maximum pressure this valve can take?
 Reply

A  Answered on 2/23/2015 by InyoPools Product Specialist Robert M.

Hello Carl - The maximum pressure rating on this valve is 50psi.
 Reply


?     Asked on 1/22/2015 by Ramon

Would this work for swimming pool as I will be using it to prevent back flow water from the filter tank and returning to the pool? This is 2" and can be used with sch 40 or 80 piping
 Reply

A  Answered on 1/22/2015 by InyoPools Product Specialist Robert M.

Hello Ramon - This valve is designed for swimming pool plumbing. You can use sch 40 or 80.
 Reply