AquaRite 25K Replacement Cell - W3T-CELL-9

$459.00

IN STOCK
FREE SHIPPING

Model # W3T-CELL-9

By Goldline Controls

  4.5 Average  

Details

Top

Model # W3T-CELL-9

Product Description

Replacement Turbo Cell for AquaRite 25,000 Gallon pools. Comes with 15' of cable and a 3 year warranty. This cell requires that you have a Power Supply with Software Revision 1.50 or higher

Product Specifications

Treatment Capacity:
25,000 gal.
Warranty:
3 yrs
Type:
O.E.M
Top

?     Asked on 5/19/2019 by Justin

I recently cleaned my salt cell because the check cell and low salt lights were blinking. After cleaning the check cell and low salt lights are lit solid. Does that mean I need to replace the cell?
 Reply

A  Answered on 5/20/2019 by Industry Professional

This does not necessarily mean that cell needs to be replaced, did you reset diagnostic button after cleaning if not then the check cell light will come on. Here is a guide On How to Determine if My Salt Cell Needs to be Replaced which you should find helpful
 Reply


?     Asked on 5/16/2019 by

What is the warranty on a trip salt cell?
 Reply

A  Answered on 5/16/2019 by InyoPools Product Specialist Lennox H.

Hi. This cell has a 3 year warranty. 
 Reply


?     Asked on 3/26/2019 by James

My cell reads 0 volts and I get inspect cell but if I cut the unit on and off then it goes back to reading within normal values and everything works fine but a day or so later it goes back to zero and I get inspect cell another reset and its ok again. cell or board?
 Reply

A  Answered on 3/27/2019 by InyoPools Product Specialist Lennox H.

Hi, James. It sounds like the Main PCB it the issue.
 Reply

  • Commented on 4/4/2019 by Product Owner

    I replaced the PCB 3 days ago everything was fine today. I go out 2 days later and its flashing low salt 0000 reading on the salt cell volts were like 23 cell amp 0. Cut it off then back on everything is working fine again the salt is reading about 3800 and it is 2950 per my test kit though. Its like the cell loses amps after a day or so.
     Reply

    • Commented on 4/5/2019 by InyoPools Product Specialist Lennox H.

      Jerimy, The cell could be failing. If you can provide the serial number I can determine the cell age. 
       Reply

    • Commented on 4/5/2019 by InyoPools Product Specialist Lennox H.

      Jerimy, The cell could be failing. If you can provide the serial number I can determine the cell age. 
       Reply


?     Asked on 2/16/2019 by neal

how do I check generator for not working t 9 cell
 Reply

A  Answered on 2/18/2019 by InyoPools Product Specialist Lennox H.

Hi, Neal. You can scroll through the Diagnostic of your system to make sure that you have the correct Cell Voltage: 22-32 VDC and Cell AmpsL 2.3-6.7 amps. 
 Reply


?     Asked on 8/11/2018 by Ron

My Aquarite T-9 is not producing chlorine. Looking at the diagnostics, the Cell Current is reading 0.0. Everything else looks normal. The cell is clean and the salt level is about 2800 or higher. Does this mean the cell is shot? Or is it the chlorinator box? Both? My T-9 is still under warranty. If the cell is shot, how do I use the warranty? Thanks for your help.
 Reply

A  Answered on 8/14/2018 by InyoPools Product Specialist Lennox H.

Hi, Ron. If everything is reading zero including the cell voltages, then the Main PCB is bad. 
 Reply


?     Asked on 5/14/2018 by David R. Yood

I have a Turbulent Flo-Chamber cell. It says Turbo Cell on the bottom. Which cell do I order?
 Reply

A  Answered on 5/18/2018 by InyoPools Product Specialist Lennox H.

Hi, David R. I will need to know the model or name of the controller, the software revision and the size of your pool in order to locate which cell you can use. 
 Reply


?     Asked on 10/2/2017 by Kevin

I have always had the t 15 cell replacement as that was the original setup, I did have to replace the mother board and now need a new cell. I know the cells have to compatible with the mother board. I now operate on r 1.58. What are my options for a cell. Pool volume is actually around 18k gallons. The t-15 was overkill but that was the original setup. Will a t-9 work on this firmware?
 Reply

A  Answered on 10/3/2017 by InyoPools Product Specialist Lennox H.

Hi, Kevin. You can use the TCELL9 with your current system, however, the TCELL9 will not last as long as the TCELL15. The larger the cell capacity to your pool the less it will have to work causing the cell to last longer. 
 Reply


?     Asked on 9/28/2017 by Raymond Burk

Can you replace the sensor on a salt cell T-9?
 Reply

A  Answered on 9/29/2017 by InyoPools Product Specialist Lennox H.

Hi, Raymond Burk. The sensor cannot be replaced, you will have to replace the entire cell. 
 Reply


?     Asked on 8/16/2016 by

Is there a repair kit for this cell? The outside plastic is leaking at the place where pieces fit together just below the top where the water comes into the cell.
 Reply

A  Answered on 8/19/2016 by InyoPools Product Specialist Stacey M.

Hello, Unfortunately this just comes as one complete cell no repair kits for TCELL9.
 Reply


?     Asked on 7/8/2016 by Maria Hoyne

I just ordered the aqua rite replacement main PCB. Will your turbo cellT-cell- 9 be compatible with it
 Reply

A  Answered on 7/8/2016 by InyoPools Product Specialist Alan M.

Yes the T-Cell 9 is compatible with the GLX-PCB-RITE main circuit board.
 Reply


?     Asked on 6/6/2016 by david lott

I have a 15 cell but i think they over killed it so how do i figure out what size pool i have?
 Reply

A  Answered on 6/7/2016 by InyoPools Product Specialist Patrick P.

Hi David, You can use this Pool Volume Calculator to figure out what size pool you have, however we do suggest oversizing the salt cell as you will get much longer life out of the cell.
 Reply


?     Asked on 3/3/2016 by steven

i need to purchase 25 K replacement cell, how do I know if I have the correct revison
 Reply

A  Answered on 3/3/2016 by InyoPools Product Specialist Lennox H.

Hi Steven, If your system originally came with a T9 cell, then you don't have to worry about the software revision. The system will tell you the software revision by scrolling through the menu or pressing the diagnostic button until you get to the software option.
 Reply


?     Asked on 4/6/2009 by Guest

I have an AquaRite which is 5 Years old and think my software is different then the new cell requires. Which cell do I need?
 Reply

A  Answered on 4/6/2009 by InyoPools Product Specialist Patrick P.

If you have an older unit (older than 2009) than you would require the GLXCELL15W which you may view or purchase here http://www.inyopools.com/Products/02100002048034.htm 
 Reply


Top

Review Summary

 (Average 4.5  out of 5 stars)
4 Rating
5 star:
 
(3)
4 star:
 
(0)
3 star:
 
(1)
2 star:
 
(0)
1 star:
 
(0)

The Most Helpful Review


The Most Recent Reviews