Raypak Heater 206000 BTU LP ELE - PR206AEP

$1,369.99

IN STOCK
FREE SHIPPING

Part # 009224

By Raypak


Details

Top

Part # 009224

Warranty 1

Manufacturer Code PR206AEP

Alternate Part #'s 009224

Product Description

BENEFITS:

  • Digital control with liquid crystal display (LCD) for temperature selection and heater settings

  • Capron resin headers prevent rust stains from harming pool surface

  • Plumb directly from provided 2" PVC threaded union

  • Smart microprocessor controls diagnostic read-out and continuously monitors operating status

  • Completely field serviceable

  • Small footprint

  • High efficiency

  • Guaranteed high wind reliability

  • Looks smart and works smart

  • 1 Year Warranty

  • Thermal Efficiency of 83% 

  

Elevation: 0 Ft. – 2000 Ft. Click Here for High Altitude Pool Heaters

California Customers Please Note:  South Coast Air Quality Management District ( SCAQMD) Area of Jurisdiction REQUIRES a Low Nox Heater be installed.  The following 6 California Counties are affected:  Los Angeles, San Bernardino, Ventura, Orange, Riverside, & Kern. Installing a non-compliant heater in these counties will void the manufacturer's  warranty and could result in a fine from your local code enforcement.    Click here for RayPak Low Nox Heaters

WARRANTY EXCLUSIONS 
This Limited Warranty does NOT apply; 
1. if the product has been moved from its original place of installation, or if the original 
owner no longer owns the property where the original installation was made; 
2. if the product is not properly installed with a pool or spa by a qualified licensed installer in 
accordance with applicable local codes and ordinances, good trade practices, and the 
manufacturer’s installation instructions; 
3. if the rating plate(s) or serial number(s) are altered or removed; 
4. if the product is modified in any way, or non-factory authorized accessories or other 
components are used in conjunction with the product; 
5. to damage, malfunctions or failures resulting from failure to properly install, operate or 
maintain the product in accordance with the manufacturer’s instructions; 
6. to damage, malfunctions or failures from abuse, act of nature, accident, fire, flood, freeze, 
lightning or the like; 
7. to damage, malfunctions or failures resulting from [or due to] connected system control 
devices; 
8. performance problems caused by improper sizing of the heater or electric service 
voltage, wiring or fusing; 
9. use of any attachment, including any energy saving device not authorized by the 
manufacturer. 
10. to damage, malfunctions or failures from misuse or neglect, including but not limited to, 
freeze-ups, operating the heater with the cabinet door off, having flow restrictions or 
obstructions between the heater outlet and the pool/spa, or not maintaining a proper 
chemical balance (PH level must be between 7.4 and 7.8 and total alkalinity between 100 
and 150 PPM. Total dissolved solids (TDS) must be no greater than 3000 PPM)

Product Specifications

BTU:
206,000 BTU
Gas:
Propane
Ignition:
Electronic
Digital Readout:
Yes
Top

?     Asked on 9/7/2017 by Mary

If I have a 24,000 gallon pool with 3/4 pool pump can I install a 266 BTU heater? I currently have a 175K heater on it's way out. Thanks

A     Answered on 9/13/2017 by InyoPools Product Specialist Patrick P.

Hi Mary, you can go with a larger heater but you will want to make sure that your gas line can support the larger heater. Here is Chart Showing the Needed Gas Line Size For Pool Heaters.

?     Asked on 6/28/2017 by linda

how far does the pool heater have to be from the house - huntington ny

A     Answered on 6/29/2017 by InyoPools Product Specialist Joe S.

For U.S. installations, the point from where the flue products exit the heater must be a minimum of 4 ft below, 4 ft horizontally from, or 1 ft above any door, window or gravity inlet into any building. The top surface of the heater shall be at least 3 ft above any forced air inlet, or intake ducts located within 10 ft horizontally

?     Asked on 6/1/2017 by nick shaieb

can I reduce the inlet and outlet to fit my 1-3/4 " hose ?

A     Answered on 6/2/2017 by InyoPools Product Specialist Lennox H.

Hi, Nick. I would not recommend using hosed with this unit.

?     Asked on 5/22/2017 by Mark

These heaters are brand new. They are not re-manufactured units. Correct?

A     Answered on 5/22/2017 by InyoPools Product Specialist Lennox H.

Hi, Mark. These are brand new units.

?     Asked on 5/16/2017 by nick

your piping chart says maximum 60', I'll be at 75', is this a problem?

A     Answered on 5/16/2017 by InyoPools Product Specialist Patrick P.

Hi Nick, Yes this would be an issue you would need to be below 60' using 3/4" gas line. Please note this measurement is from the Distance  from  Tank   Regulator Outlet at your propane tank to the Heater Gas Valve Inlet.

?     Asked on 5/16/2017 by nick

Ordered your pr206aep from you yesterday, but I noticed this morning on your pipping chart, that 3/4" pipe is good out to 60'. The location of our tank will be 75'. Will this be a problem?

A     Answered on 5/16/2017 by InyoPools Product Specialist Patrick P.

Hi Nick, Yes this would be an issue you would need to be below 60' using 3/4" gas line. Please note this measurement is from the Distance from  Tank   Regulator Outlet at your propane tank to the Heater Gas Valve Inlet. I would call our customer service department at 407-834-2200 to discuss options about your order.

?     Asked on 5/9/2017 by

Could I please get the dimensions of this heater? Thanks,

A     Answered on 5/9/2017 by InyoPools Product Specialist Hector F.

Please click here to view the dimensions and technical data for these units.

?     Asked on 5/9/2017 by Steve

How wide is thepr206aep

A     Answered on 5/9/2017 by InyoPools Product Specialist Hector F.

Please click here for the technical data on these units.

?     Asked on 5/9/2017 by Steve

How wide is thepr206aep

A     Answered on 5/9/2017 by InyoPools Product Specialist Hector F.

Please click here to view all the dimensions and technical data on these units.

?     Asked on 3/30/2017 by Rich

I am replacing a Rapak 2100 Natural Gas 180,000 BTU so what is the difference between Mod# PR206AMP and PR206AEP? Does the M = Millvolt and E= Electric

A     Answered on 3/31/2017 by InyoPools Product Specialist Scott W.

Yes, that would be the difference between the two, but you would want the natural gas model either PR206AMN or PR206AEN.

?     Asked on 3/19/2017 by Jax Banks

I currently have a RP2100 pool/spa heater. I have NEVER tried to heat the pool, only the spa. Can I use a smaller propane/electric start heater to heat ONLY the spa?

A     Answered on 3/21/2017 by InyoPools Product Specialist Lennox H.

Hi, Jax. Yes, you can use a smaller unit if you want to heat just your spa depending on the surface area of the spa. You can use our BTU Sizing Chart for more info.

?     Asked on 5/29/2016 by

I have a Raypak 2100 Digital pool heater and when I try to turn it on, it reads PLT on the display. I believe this is a electronic function and I do not know how to restart the heater.

A     Answered on 5/30/2016 by InyoPools Product Specialist Alex V.

The "PLT" error code means pilot failure. The lack of spark may or may not mean an ignitor problem. I have seen the "PLT" code come up because the main valve in the heater was in the "off" position. No gas = no pilot. Have also seen clogged pilot-burner orifices. The lack of spark may have to do with water flow issues (dirty filter, clogged basket, etc.), or it may be a problem with the electronics of the heater.All of these (except turning the gas valve on) will require a competent service tech to diagnose.

?     Asked on 5/28/2016 by gerald claxton

i live in kern county ca in the mountains we get snow. can 206000 btu lp ele #009224 work???

A     Answered on 6/4/2016 by InyoPools Product Specialist Lennox H.

Hi Gerald, To recommend a Heater for you we will need to know the following information: pool surface area, elevation, zip code, gas type .

?     Asked on 5/23/2016 by

Can this heater be converted easily to natural gas?

A     Answered on 5/23/2016 by InyoPools Product Specialist Patrick P.

Unfortunately the conversion of this heater from Proprane to Natural would must be made with a complete burner tray and gas valve replacement.

?     Asked on 3/14/2016 by

How many btu to heat one gallon of water 1 degree.

A     Answered on 3/15/2016 by InyoPools Product Specialist Lennox H.

Hi, A gas heater uses about 11 BTU to heat 1 gallon of water 1 degree.

?     Asked on 12/1/2015 by Shawn

How much power does this draw? Need a new Heater and considering switching my filter and heater to run in solar power.

A     Answered on 12/2/2015 by InyoPools Product Specialist Lennox H.

Hi Shawn, According to the RP Series Technical Data Sheet this unit can draw 4 amp using 120 volts or 2 amps using 240 volts.

?     Asked on 7/7/2015 by Randy

Can a PR266A-MP Propane Heater be converted to a PR266A-MN Natural Gas Heater?

A     Answered on 7/9/2015 by InyoPools Product Specialist Matt S.

Hello Randy, the conversion kit for Propane to Natural  gas for a 266K Raypak MV is part number 010419F.  As with the initial installation, the conversion of the heater gas type should only be completed by a licensed professional.

?     Asked on 6/22/2015 by robert

Does this heater have electronic ignition?

A     Answered on 6/22/2015 by InyoPools Product Specialist Lennox H.

Robert, The Raypak Heater 206000 BTU LP ELE (009224) does have an electronic ignition.

?     Asked on 5/9/2015 by KEVIN

?I NEED A POOL HEATER FOR OUR POOL, GAS HEATER, THERE IS ONE IN PLACE BUT IT IS OLD AND NEEDS TO BE REPLACED, WE ALSO NEED THE NEW HEATER INSTALDED, HOW MUCH WOULR THIS COST,

A     Answered on 5/10/2015 by InyoPools Product Specialist Joe S.

Good afternoon Kevin attached is a link to the heaters we sell. We do not offer a install service.

?     Asked on 10/10/2012 by Guest

What is the difference between an Electronic and Millivolt ignition?

A     Answered on 10/10/2012 by InyoPools Product Specialist Patrick P.

The basic answer is that Millivolt is the old style of ignition, using a standing pilot light. While the electronic ignition uses a spark start system like a gas grill. Electronic ignitions are more efficient in gas usage and also are better suited for high wind areas where a pilot light might get extinguished.

?     Asked on 1/16/2012 by Guest

Will a gas heater operate at the low speed of a dual speed motor?

A     Answered on 1/16/2012 by InyoPools Product Specialist Patrick P.

Probably not - Most gas heater will shut off at low GPM levels (20-40) to keep the heater cores from overheating - 20 for 200 BTUs, 40 for 400 BTUs. Depending on your pool system you might get these GPM levels at the low speed but generally these heaters must be run at the motor's high speed.

?     Asked on 4/30/2007 by Guest

What are the dimmensions of this heater?

A     Answered on 4/30/2007 by InyoPools Product Specialist Patrick P.

This heater is 20 inches wide X 28 inches deep and 40 inches tall. 