By Raypak


Details

Top

Part # 010745

Warranty 1 Year

Alternate Part #'s RAY010745

Product Description

The D-2 Power Vent is a fan-assisted combustion system designed for application to heater models 206 through 407. When installed as directed, the unit is capable of operating in applications such as through-the-wall venting and reduced horizontal and vertical vent pipe sizes in new and existing installations.

Through-the-Wall Capable
The D-2 Power Vent assembly is a Category III mechanical draft venting system that operates with a positive vent static pressure and with a vent gas temperature that avoids excessive condensate production in the vent. All sizes are capable of relieving flue gases up to a maximum of 100 equivalent feet of vent length. All models have a 4” diameter exhaust connection and can be sidewall terminated using field-supplied cat III-certified vent material. Use the factory-supplied screened elbow as a downturned sidewall vent termination.

Compatible for indoor or outdoor installation
For use with all Raypak Digital models, sizes 206A - 408.  The D-2 replaces the standard draft hood.

Certified
The D-2 Power Vent assembly is tested and certified to the latest edition of the American National Standard ANSI Z21.56 for pool heaters.


Multi-Position
Using a field-supplied adjustable 90° elbow, the flue gases may be discharged in any direction (see D-2 Power Vent manual for details). Or simply remove the elbow for vertical venting.

Dual-Voltage Induced-Draft Blower (120/240 VAC)

Factory set for 240 volts. Can be rewired in the field for 120v operation.

Safety at Its Best
The D-2 Power Vent is equipped with a draft proving switch. This switch ensures that the blower is operating before operating your heater. It is also equipped with a solid state control that allows the blower to purge any residual gas buildup in the heater after the heater has shut down.

 

Features

  • Induced draft
  • Vent (Category III) runs up to 100 ft. equivalent length
  • Plenum sized for appliance capacity
  • Air flow proving switch, mounted and wired
  • Fan motor relay, mounted and wired
  • 240/120 Volt, 60 Hz, 1.95/1.0 Amp, 130 CFM Max., 3200 RPM motor; Factory-wired for 240 Volt
  • 90° elbow is used as a termination cap for horizontal venting
  • Heavy-duty galvanized steel cabinet
  • PolyTuf textured powder coat finish
  • Indoor/Outdoor construction
  • Easy installation
  • Limited one-year warranty
  • Shipped loose for field mounting

Product Specifications

Volts:
120 V
Model:
336A-407A
Top

?     Asked on 5/9/2017by EDMUNDO JAVIER SALAS TREVIÑO

I would like you recommend to me the heater raypak 335000 BTU elec lp cupro nikelworks with the D-2 power Vent (010745)
 Reply

A  Answered on 5/10/2017 by InyoPools Product Specialist Lennox H.

Hi, Edmundo. The Raypak Heater 336,000 BTU's LP ELE W/ Cupro-Nickel Heat Exchanger - 014952 is the standard residential unit. If you need a specific unit please let us know.
 Reply