$3,289.00
By CAT Controllers, Inc.
Part # W3CATPP2000
Warranty 5 Year
The CAT 2000 Professional Package is a complete, factory-assembled automation system which includes a CAT 2000 controller, Professional Series sensors, machined acrylic flow cell, rotary flow sensor and PVC backboard.
The CAT 2000 Professional Package automated controller is the water quality solution for pools, spas, waterparks and a multitude of other water treatment applications world-wide.
The powerful microprocessor-based design makes simple science of water chemistry maintenance under even the most challenging conditions. Constantly monitoring pH and sanitizer activity (chlorine, bromine, even salt systems) and implements chemical dosing in proportion to demand. This proportional feed capability ensures precise water conditioning without overfeeding.
And for superior bacteriological water quality, CAT controllers operate utilizing the Oxidation-Reduction Potential (ORP) method of water analysis. ORP is the only reliable method proven to ensure rapid deactivation of such waterborne pathogens as E. Coli in swimming pool water.
With the power to meet the demands of virtually any application, the price to please the fiscally conscious, and the simplicity to assure success in the field, the CAT 2000 is the no-compromise solution to your water chemistry control requirements..
The CAT 2000 is compatible with existing chemical feeding equipment, and is shipped complete with sensors, installation hardware, and a comprehensive installation and operation guide.
Advantages:
CAT 2000 SPECIFICATIONS | ||
Display Range | pH | 1.0 - 9.95 |
ORP | 5 - 995 mV | |
Setpoint Range | pH | 7.0 - 8.0 |
ORP | 200 - 995 mV | |
Control Accuracy | pH | +/- 0.1 pH |
ORP | +/- 5.0 mV | |
Mode Selections | pH | Automatic / Off / Manual Proportional or Direct Feed |
ORP | Automatic / Off / Manual Proportional or Direct Feed |
|
pH Feed | Acid or Base Feed | |
pH Mode | Auto / Set / Calibrate | |
ORP Mode | Auto / Set | |
Safety Systems | pH | Audible / Visual Safeguard Alarms Adjustable Overfeed Timer pH Priority Control |
ORP | Audible / Visual Safeguard Alarms Adjustable Overfeed Timer |
|
Controller Unit | Diagnostic Self-Test | |
Required | Rotary or Pressure Flow Sensor | |
Optional | Remote Alarm | |
Outputs | pH Feed | 4 Amp, 120/230 VAC 4 Amp, Dry Contact |
ORP Feed | 4 Amp, 120/230 VAC 4 Amp, Dry Contact |
|
Remote Alarm | 4 Amp Dry Contact | |
Serial | RS232 Serial Interface | |
Power Requirements | USA | 15 Amp, 120 VAC 60 HZ |
International | 10 Amp, 230 VAC 50/60 HZ |
Have a cat 2000 controller. Problem PH pump won't run in Auto or Manual. Tested Pump runs on extension cord, tested with meter fuses have continuity, Tested no power at terminal block in Auto or Manual. Tested unplug PH probe dropped reading to .3 plug probe back shows 7.4.. Ideas on the problem?
Reply
We apologize for the inconvenience, however, we are not certified by Hayward to troubleshoot this system. We suggest speaking to them directly. You can call them at 800.429.9273.
Reply