By Hayward Pool Products
Part # HCC2000-AU
Warranty Controller 1 Year Comprehensive, Sensors 1 Year Comprehensive
Automated water quality solution for pools, spas, water parks and more, world-wide.
Hayward HCC 2000 HCC2000 Water Chemistry Controller. Perfect for swimming pools, spas and water features, the HCC 2000 is a powerful yet affordable microprocessor-based pH/ORP water chemistry controller. The controller features proportional feed to ensure precise water chemistry maintenance. It operates using the Oxidation-Reduction Potential (ORP) method of water analysis to ensure rapid deactivation of waterborne pathogens such as E. coli.
Enclosed in the packaging, you should find all of the following:
HCC 2000 controller scans and interprets the signals from the pH and ORP probes, displays water quality readings in digital format, and activates chemical feeders in proportion to the demand required to maintain setpoint pH and ORP levels. The unit incorporates audible and visual safeguard alarms for out-of-range conditions, calibration adjustment for pH, and mode selections to manually feed or disable feeding for either channel. The HCC 2000 controller unit also features an internal micro-computer for unsurpassed accuracy, adaptability, and ease of use. All user entries and adjustments are made through the touch-screen interface front panel. The Flow Cell provides a convenient location for mounting the pH, ORP, and Flow Sensor while ensuring ideal hydraulic conditions to maximize sensor performance and life.
Flow Cell provides a convenient location for mounting the pH, ORP, and Flow Sensor while ensuring ideal hydraulic conditions to maximize sensor performance and life.
Flow Sensor (required) monitors the rate of flow across the pH and ORP sensors and signals the controller to disable automated chemical feeding during periods when the filtration system is off or low recirculation flow is detected.
pH Sensor samples water from the filtration system and sends signals to the controller indicating the acidity of the water. The ideal pH range for pools and spas is 7.4 - 7.6. The HCC 2000 controller is preset from the factory to maintain pH 7.5. If pH is maintained below 7.4 (too acidic), eye irritation, corrosion of equipment, and damage to the pool or spa surface can occur. If pH is maintained above 7.6 (too alkaline), sanitizer activity is reduced, water may become cloudy, and eye irritation may result.
ORP Sensor samples water from the filtration system and sends signals to the controller indicating the oxidation-reduction potential (redox) of the water. ORPis an actual measure of sanitizer activity (chlorine, bromine, ozone, etc.) and bacteriological water quality rather than an expression of chemical residual levels. The HCC 2000 controller is preset from the factory to maintain ORPat 650 millivolts.
HCC 2000 SPECIFICATIONS | ||
Display Range | pH | 1.0 - 9.95 |
ORP | 5 - 995 mV | |
Setpoint Range | pH | 7.0 - 8.0 |
ORP | 200 - 995 mV | |
Control Accuracy | pH | +/- 0.1 pH |
ORP | +/- 5.0 mV | |
Mode Selections | pH | Automatic / Off / Manual Proportional or Direct Feed |
ORP | Automatic / Off / Manual Proportional or Direct Feed |
|
pH Feed | Acid or Base Feed | |
pH Mode | Auto / Set / Calibrate | |
ORP Mode | Auto / Set | |
Safety Systems | pH | Audible / Visual Safeguard Alarms Adjustable Overfeed Timer pH Priority Control |
ORP | Audible / Visual Safeguard Alarms Adjustable Overfeed Timer |
|
Controller Unit | Diagnostic Self-Test | |
Required | Rotary or Pressure Flow Sensor | |
Optional | Remote Alarm | |
Outputs | pH Feed | 4 Amp, 120/230 VAC 4 Amp, Dry Contact |
ORP Feed | 4 Amp, 120/230 VAC 4 Amp, Dry Contact |
|
Remote Alarm | 4 Amp Dry Contact | |
Serial | RS232 Serial Interface | |
Power Requirements | USA | USA - 10 Amp, 120 VAC 60 Hz |
International | Intl. - 5 Amp, 240 VAC 50/60 Hz |