Details

Top

Model # GRCJ40-3

Warranty 2 Year warranty

Product Description

Replacement Salt Cell for Jandy Aqua Pure 1400

The GRC/J40-3 is a generic 3-port replacement salt cell for the Jandy Aqua Pure 1400, PLC1400 and Clormatic Salt Systems. Our generic salt cells are manufactured by CompuPool who has 35 years experience in manufacturing and is one of the largest manufactures of salt water systems in the world. When purchasing a replacement salt cell from INYOpools.com you are getting rock bottom pricing and a 2 year warranty with this combination you can’t go wrong!

Commonly Used On

When replacing a Jandy PLC700 or PLC1400 salt cell you will use the flow switch from your old salt cell, this flow switch screws into the bottom port of the aftermarket salt cell. You will also use current unions from your Jandy cell that will screw onto this after-market cell. The ports without unions on the 3 port cell measure 3-1/4" in diameter if your ports measure 3" in diameter then you will require the 2-Port After-Market Jandy Cell

Product Specifications

Cord Length:
16 ft.
Treatment Capacity:
40,000 gal.
Type:
After Market
Top

?     Asked on 6/1/2017 by Kevin

Can I get the jandy aqua pure replacement marine generator with a 25 foot cord the 15 foot cord would not be long enough. Is there somebody else I can ask her to go to like the manufacturer directly to find out if they can do that as a special order?
 Reply

A  Answered on 6/3/2017 by InyoPools Product Specialist Lennox H.

Hi, Kevin. Unfortunately, the manufacturer does not have or able to special order this cell with a longer cord.
 Reply


?     Asked on 5/31/2017 by

I have a CM 601 power supply and a CMC 1400 chlormatic cell will this cell be a match
 Reply

A  Answered on 6/4/2017 by InyoPools Product Specialist Lennox H.

Hi. This Aftermarket Cell can be used as a replacement.
 Reply


?     Asked on 4/29/2017 by Bill

I purchased a compupool 14 blade salt cell for my Jandy system. It fits fine except the wiring on the compupool unit is totally different then the Jandy the connections from the Jandy unit are two wires. a black wire with a white stripe and a green wire. The wires coming from the compupool salt cell are; a Black wire and blue wire connected at the end and a Red wire. How do I wire this? Thank you VERY much for your help.
 Reply

A  Answered on 4/30/2017 by InyoPools Product Specialist Lennox H.

Hi, Bill. The aftermarket cell wiring is as follows, the wire that is all alone is to be plugged into the green terminal (-) on the board and the paired wire to the black and white (+) terminal on the board.
 Reply


?     Asked on 4/4/2017 by

Does this salt cell come with the flow sensor that comes out of the bottom of current Jandy cell?
 Reply

A  Answered on 4/4/2017 by InyoPools Product Specialist Patrick P.

No the flow sensor is not included. You will use the Jandy aqua pure flow sensor from your current Jandy salt cell, simply unscrew the flow sensor from the old cell, place the flow sensor in the bottom port of the new salt cell and secure with the union from your old cell.
 Reply


?     Asked on 4/4/2017 by

Does the aftermarket Jandy 3 Port Cell come with unions?
 Reply

A  Answered on 4/4/2017 by InyoPools Product Specialist Patrick P.

No the unions are not included, you would use the unions off of your old Jandy AquaPure salt cell and use those unions on the new cell as they are a perfect match. If for some reason you need new Unions then here are the Jandy AquaPure Replacement Unions.
 Reply


?     Asked on 3/30/2017 by Theresa

We have a Jandy PLC700 that needs to be replaced, because our pool holds approximately 38,000 gallons. Will this generic be an easy swap out or an exact swap out?
 Reply

A  Answered on 3/31/2017 by InyoPools Product Specialist Scott W.

Yes, the GRCJ40-3 will be a direct swap out of your original cell.
 Reply


?     Asked on 3/25/2017 by

My Jandy 3 port cell this will replace has a plug on the side. I see in the pictures this one does not have the plug. Are they available seperately?
 Reply

A  Answered on 3/29/2017 by InyoPools Product Specialist Patrick P.

Most likely your Jandy cell has two cables coming out of it. One is called the Power cable and on the Jandy original this plugs into 3 prongs coming off of the salt cell. For the new aftermarket cell you will no longer use your Jandy cable as the aftermarket cell comes with a power supply cable that is integrated directly into the cell and will plug into your power supply. The second cable coming off of your Jandy cell is the flow sensor cable this will come out of the bottom port of the cell. When using this aftermarket cell you will unscrew your the flow sensor from your old Jandy cell and screw that sensor into the new cell.
 Reply


?     Asked on 3/20/2017 by Harold Buchanan

Can the three contacts that protrude from the original Aqua pure 1400 cell be replaced? If not is the cell recyclable? What is the material used to manufacture the fins?
 Reply

A  Answered on 3/21/2017 by InyoPools Product Specialist Alan M.

The three prongs are not a replaceable part for this cell. I do not believe that the cell is recyclable. you would need to contact the manufacturer directly at 1-800-822-7933 to answer the question on the material the metallic plates are made from.
 Reply


?     Asked on 3/14/2017 by Bob

Does this model allow the slotted Jandy flow and temp transmitter to fit properly
 Reply

A  Answered on 3/15/2017 by InyoPools Product Specialist Patrick P.

Yes this model does accommodate the Jandy slotted flow and temperature sensor. You will use your current flow sensor and this sensor is placed into the bottom port of the cell, you will then use the union from your current cell to secure the flow sensor to the bottom port of the new cell. The only difference between these and the original is that the power cord is integrated into this cell.
 Reply


?     Asked on 3/12/2017 by Maui Myers

Is this OEM model a direct replacement for the Aqua Pure PLC 1400 Zodiac 3 Port Cell? Please identify if this is a swap out capable replacement for the Jandy Aqua Pure Zodiac PLC1400 14 blade 3 port cell. Thank you.
 Reply

A  Answered on 3/12/2017 by InyoPools Product Specialist Patrick P.

Hi Maui, Yes this salt cell is a direct replacement for the Aqua Pure PLC 1400 Zodiac 3 Port Cell, it is a direct swap out.
 Reply


?     Asked on 2/29/2012 by Guest

Is the salt included with the salt chlorine generator?
 Reply

A  Answered on 2/29/2012 by InyoPools Product Specialist Patrick P.

No, salt is not included.  You would purchase the salt locally and the quantity will depend upon the number of gallons of water in your pool.  Use a salt that is at least 99.8% pure NaCl. The preferred salt is evaporated, granulated, food quality, and NON-iodized.  Avoid using salt with anti-caking agents like sodium ferrocyanide, also known as yellow YPS (prussiate of soda). These cause some discoloration of fittings and pool surface finishes. DO NOT use calcium chloride.
 Reply


Top
Difficulty

Est. Repair Time

1 to 2 hrs

Tools Needed

Screwdriver, Adjustable Wrench, Strap Wrenches (to protect from damaging plumbing coupling connections)

2     2

Jandy Salt Cell not working / Replaced with CompuPool unit

Written on 8/8/2017 by Neil D.

1 Turn off Power, 2 Relieve system Pressure, 3 Isolate salt cell to be replace (may be first step dependent on how system is plumbed. 4 Remove sensor cell from old unit. 5 Remove old cell from system. 6 WITHOUT STRESSING THE CONNECTIONS ON THE MOTHER BOARD, disconnect and remove power cable from motherboard control to Jandy saltcell. 7, Install new CompuPool salt cell in system (Note: Inlet is on the power cable end of CompuPool Salt cell), 8 RE--iInstall sensor cell into new unit. 9 Route power cable from salt cell to motherboard. 10. CAREFULLY RECONNECT CABLE PUSH CONNECTORS TO MOTHERBOARD. make sure orientation matches motherboard label (Green to Green/Black and White to Black and White). 11 Un-isolate salt cell in plumbing, 12 re-energize system, and start pumps. 13 Check for leaks at new salt cell, Check flow sensor after five minute run-in to insure system is showing flow and cell is operating. Note: the new cell with the clear bell my actually show some gas being generated almost immediately. Good indicator that cell is functioning properly.

Were these instructions helpful?